sales06@switek.biz
+86 186 5927 5869
Description | Unit | Value |
---|---|---|
INJECTION UNIT | ||
Shot volume | cm3 | 3925 |
Shot weight | g | 3572 |
Shot speed | mm/s | 918 |
Screw diameter | mm | 100 |
Injection pressure | MPa | 191 |
Screw L:D ratio | -- | 22 |
CLAMPING UNIT | ||
Clamping force | kN | 10000 |
Opening Stroke | mm | 1800 |
Space between tie bars | mm x mm | 1250 x 1100 |
Mold thickness(min) | mm | 600 |
Mold thickness(max) | mm | 1200 |
Hydraulic ejection stroke | mm | 300 |
Hydraulic ejection force | kN | 350 |
POWER UNIT | ||
Pump motor | kW | 120 |
Heating capacity | kW | 49 |
GENERAL | ||
Oil tank capacity | L | 1800 |
Platen Dimension
Machine Dimmension
# | Value |
---|---|
A | 2990 mm |
B | 1508 mm |
C | 1482 mm |
D | 1332 mm |
E | 1306 mm |
F | 2400 mm |
G | 1800 mm |
H | 1498 mm |
I | 1884 mm |
J | 1526 mm |
K | 1738 mm |
L | 2491 mm |
M | 2139 mm |
N | 2286 mm |
Why it's not recommended to have an IML solution with more than 4 cavities for containers which request a wrap+bottom labeling?
For an IML container which request a wrap + bottom labeling will need 2 labels and request a reverse injection technology. With two labels means that there would be 2 sets of magazines and mandrel to stock and pick the labels for the containers. A four cavities design of the mold there would be sufficient space in the IML robot to fit in the extra magazines, but for more cavities mold design the size of the magazine will exceed the limit of the IML robot and will reduce the efficiency of the robot. It would not be an ideal solutions for Wrap + Bottom IML Solutions