Description | Unit | Value |
---|---|---|
INJECTION UNIT | ||
Shot volume | cm3 | 214 |
Shot weight | g | 195 |
Shot speed | mm/s | 200 |
Screw diameter | mm | 38 |
Injection pressure | MPa | 199 |
Screw L:D ratio | -- | 23.2 |
CLAMPING UNIT | ||
Clamping force | kN | 1400 |
Opening Stroke | mm | 380 |
Space between tie bars | mm x mm | 420 x 420 |
Mold thickness(min) | mm | 140 |
Mold thickness(max) | mm | 440 |
Hydraulic ejection stroke | mm | 115 |
Hydraulic ejection force | kN | 38 |
POWER UNIT | ||
Pump motor | kW | 13 |
Heating capacity | kW | 12.7 |
GENERAL | ||
Oil tank capacity | L | 170 |
Robot Installation
Platen Dimension
Machine Dimmension
# | Value |
---|---|
A | 4800 mm |
B | 2700 mm |
C | 535 mm |
D | 355 mm |
E | 60 mm |
F | 1550 mm |
G | 2050 mm |
H | 2050 mm |
I | 684 mm |
J | 1850 mm |
K | 3720 mm |
L | 1630 mm |
M | 860 mm |
N | 900 mm |
O | 1350 mm |
Why it's not recommended to have an IML solution with more than 4 cavities for containers which request a wrap+bottom labeling?
For an IML container which request a wrap + bottom labeling will need 2 labels and request a reverse injection technology. With two labels means that there would be 2 sets of magazines and mandrel to stock and pick the labels for the containers. A four cavities design of the mold there would be sufficient space in the IML robot to fit in the extra magazines, but for more cavities mold design the size of the magazine will exceed the limit of the IML robot and will reduce the efficiency of the robot. It would not be an ideal solutions for Wrap + Bottom IML Solutions