sales06@switek.biz
+86 186 5927 5869
Description | Unit | Value |
---|---|---|
INJECTION UNIT | ||
Shot volume | cm3 | 915 |
Shot weight | g | 833 |
Shot speed | mm/s | 190 |
Screw diameter | mm | 65 |
Injection pressure | MPa | 132 |
Screw L:D ratio | -- | 21 |
CLAMPING UNIT | ||
Clamping force | kN | 2650 |
Opening Stroke | mm | 560 |
Space between tie bars | mm x mm | 585 x 565 |
Mold thickness(min) | mm | 200 |
Mold thickness(max) | mm | 600 |
Hydraulic ejection stroke | mm | 150 |
Hydraulic ejection force | kN | 70 |
POWER UNIT | ||
Pump motor | kW | 22 |
Heating capacity | kW | 24.7 |
GENERAL | ||
Oil tank capacity | L | 300 |
Robot Installation
Platen Dimension
Machine Dimmension
# | Value |
---|---|
A | 6450 mm |
B | 3430 mm |
C | 735 mm |
D | 390 mm |
E | 60 mm |
F | 2000 mm |
G | 1510 mm |
H | 1290 mm |
I | 765 mm |
J | 2400 mm |
K | 4920 mm |
L | 1920 mm |
M | 1060 mm |
N | 1100 mm |
O | 1600 mm |
Why it's not recommended to have an IML solution with more than 4 cavities for containers which request a wrap+bottom labeling?
For an IML container which request a wrap + bottom labeling will need 2 labels and request a reverse injection technology. With two labels means that there would be 2 sets of magazines and mandrel to stock and pick the labels for the containers. A four cavities design of the mold there would be sufficient space in the IML robot to fit in the extra magazines, but for more cavities mold design the size of the magazine will exceed the limit of the IML robot and will reduce the efficiency of the robot. It would not be an ideal solutions for Wrap + Bottom IML Solutions
Hot Injection Automation News
Chinapals 2023 | HMD Working with SWITEK for Higher Speed IML Solutions for Lids
E-mail: sales@switek.biz
Contact Blogger
sales06@switek.biz
+86 186 5927 5869
DongGuan, GuangDong, China